Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 5, 2020, 09:54 AM
  • 02 0390_02 0389 _08052020_031038.mp4

Date
08/05/2020
W/O
844297
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00250
PipeID
P02709
Time
2:54 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7898
Sewer Name
DOWNEY AVENUE EXTENSION TRUNK
City
PARAMOUNT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_844297_TV02379_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
02 0390
Downstream MH
02 0389
Dir. of Survey
Downstream
Length Surveyed
397.1 ft.
Total Length
397.1 ft.
Structural Index
2
Structural Quick
3N2O
Structural Rating
389
O&M Index
2
O&M Quick
2O00
O&M Rating
158
Overall Index
2
Overall Quick
Overall Rating
547
Pipe schematic from manhole 02 0390 to 02 0389
MH: 02 0390MH: 02 0389downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 03902 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start305.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN309.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"395 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish395.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish395.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish397.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE397.1 ft. MGO - General Observation - ROACHES @ MH397.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0389

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    397.1 ft. - General Observation - ROACHES @ MH

Observations (14)

DistanceCodeObservation
0MWL
2SSS
397.1MGOCONN @ MH 3 O'CLOCK/ACTIVE
395.2DAGS
0MWM
2DAGS
397.1MGOROACHES @ MH
305.5TFOPEN
0AMH02 0390
397.1AMH02 0389
395.2CM
395SSS
2CM
309.8TFC

Properties (7)

additional_info
SC411738
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2020-08-05T02:54:18-07:00
documentation
PRO PIPE
is_lateral_inspection
false