Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2020, 10:49 AM
  • 05 1392_05 1305A_08102020_035246.mp4

Date
08/10/2020
W/O
844677
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06613
Time
3:49 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7943
Sewer Name
MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_844677_TV05074_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
18 in.
Upstream MH
05 1392
Downstream MH
05 1305A
Dir. of Survey
Downstream
Length Surveyed
46.2 ft.
Total Length
46.2 ft.
Structural Index
3
Structural Quick
3928
Structural Rating
43
O&M Index
2
O&M Quick
2800
O&M Rating
16
Overall Index
2
Overall Quick
Overall Rating
59
Pipe schematic from manhole 05 1392 to 05 1305A
MH: 05 1392MH: 05 1305Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 13920 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE0 ft. MGO - General Observation - ROACHES @ MH2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start44 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish44 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish46 ft. MGO - General Observation - ROACHES @ MH46.2 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE46.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1305A46.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
0AMH05 1392
0MWM
46MGOROACHES @ MH
44SSS
2SSS
44DAGS
46.2MGOCONN @ MH 3 O' CLOCK/ACTIVE
0MWL
3.6CM
46.2AMH05 1305A
2DAGS
0MGOCONN @ MH 3 O' CLOCK/ACTIVE
0MGOROACHES @ MH
46.2CM

Properties (7)

additional_info
SC411805
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-08-10T03:49:15-07:00
documentation
PROPIPE
is_lateral_inspection
false