Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 11, 2020, 09:30 AM
  • 05 1386_05 1385_08112020_023426.mp4

Date
08/11/2020
W/O
844677
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06606
Time
2:30 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7945
Sewer Name
MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_844677_TV05074_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
8 in.
Upstream MH
05 1385
Downstream MH
05 1386
Dir. of Survey
Upstream
Length Surveyed
48.8 ft.
Total Length
48.8 ft.
Structural Index
3
Structural Quick
3929
Structural Rating
45
O&M Index
2
O&M Quick
2900
O&M Rating
18
Overall Index
2
Overall Quick
Overall Rating
63
Pipe schematic from manhole 05 1385 to 05 1386
MH: 05 1385MH: 05 1386upstream0 ft. MGO - General Observation - CONN @ MH 9 O' CLOCK/ACTIVE0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 05 13860 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE0.8 ft. MGO - General Observation - ROACHES @ MH2.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish44.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start46.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start46.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start48.8 ft. AMH - Downstream Manhole, Survey Begins - 05 138548.8 ft. MWM - Water Mark, 25 %of cross sectional area48.8 ft. MWL - Water Level, 20 %of cross sectional area48.8 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
48.8MGOCONN @ MH 9 O' CLOCK/ACTIVE
46SSS
2SSS
48.8CM
48.8AMH05 1386
46DAGS
48.8MGOCONN @ MH 3 O' CLOCK/ACTIVE
48MGOROACHES @ MH
4.5CM
0AMH05 1385
0MWM
2DAGS
0MWL
0MGOCONN @ MH 3 O' CLOCK/ACTIVE

Properties (7)

additional_info
SC411807
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-08-11T02:30:24-07:00
documentation
PROPIPE
is_lateral_inspection
false