Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 12, 2020, 07:37 AM
  • 05 1378_05 1377_08122020_005017.mp4

Date
08/12/2020
W/O
844677
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06597
Time
12:37 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7947
Sewer Name
MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_844677_TV05074_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1377
Downstream MH
05 1378
Dir. of Survey
Upstream
Length Surveyed
349.8 ft.
Total Length
349.8 ft.
Structural Index
3
Structural Quick
3M2M
Structural Rating
342
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
344
Pipe schematic from manhole 05 1377 to 05 1378
MH: 05 1377MH: 05 1378upstream0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE0 ft. MGO - General Observation - CONN @ MH 9 O' CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 05 13780.8 ft. MGO - General Observation - ROACHES @ MH2.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish67.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"116.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"165.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"211.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN281.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - 40% GREASE-LATERAL/OPEN342.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start347.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start349.8 ft. AMH - Downstream Manhole, Survey Begins - 05 1377349.8 ft. MGO - General Observation - ROACHES @ MH349.8 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE349.8 ft. MWM - Water Mark, 25 %of cross sectional area349.8 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
0AMH05 1377
0MGOROACHES @ MH
349.8CM
2SSS
349.8MGOCONN @ MH 3 O' CLOCK/ACTIVE
67.9TFD40% GREASE-LATERAL/OPEN
282.5TFC
7.3CM
137.9TFC
349.8MGOCONN @ MH 9 O' CLOCK/ACTIVE
124.7TFOPEN
349.8AMH05 1378
0MGOCONN @ MH 3 O' CLOCK/ACTIVE
233.4TFC
349MGOROACHES @ MH
184.3TFC
347SSS
0MWM
0MWL

Properties (7)

additional_info
SC411809
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-08-12T00:37:16-07:00
documentation
PROPIPE
is_lateral_inspection
false