Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2020, 11:21 AM
  • 05 1391_05 1390_08102020_043520.mp4

Date
08/10/2020
W/O
844699
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06611
Time
4:21 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7944
Sewer Name
MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_844699_TV05336_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
8 in.
Upstream MH
05 1390
Downstream MH
05 1391
Dir. of Survey
Upstream
Length Surveyed
393.2 ft.
Total Length
393.2 ft.
Structural Index
3
Structural Quick
4O3O
Structural Rating
702
O&M Index
2
O&M Quick
2O00
O&M Rating
156
Overall Index
3
Overall Quick
Overall Rating
858
Pipe schematic from manhole 05 1390 to 05 1391
MH: 05 1390MH: 05 1391upstream0 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED0 ft. MGO - General Observation - VERMIN @ MH (1) RAT0 ft. AMH - Upstream Manhole, Survey Ends - 05 13910.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.2 ft. MGO - General Observation - ROACHES @ MH2.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish38.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"90 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN136.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"187.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN243.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"292 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"343.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"390.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start391.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start391.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start391.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start393.2 ft. MGO - General Observation - ROACHES @ MH393.2 ft. MWM - Water Mark, 10 %of cross sectional area393.2 ft. MWL - Water Level, 5 %of cross sectional area393.2 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/393.2 ft. AMH - Downstream Manhole, Survey Begins - 05 1390

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (25)

DistanceCodeObservation
391SSS
2DAGS
256.9TFC
205.7TFOPEN
393.2MGOCONN @ MH 3 O' CLOCK/ACTIVE
0MGOROACHES @ MH
354.6TFC
2SSS
393.2MGOCONN @ MH 9 O'CLOCK/CAPPED
303.2TFOPEN
149.8TFC
50TFC
393FM
101.2TFC
391CM
0MWM
0MWL
0MGOCONN @ MH 3 O' CLOCK/
393.2MGOVERMIN @ MH (1) RAT
2CM
393.2AMH05 1391
391DAGS
393MGOROACHES @ MH
0AMH05 1390
3FM

Properties (7)

additional_info
SC411806
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2020-08-10T04:21:11-07:00
documentation
PROPIPE
is_lateral_inspection
false