Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 11, 2020, 07:31 AM
  • 05 1385_05 1384_08112020_022946.mp4

Date
08/11/2020
W/O
844699
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06605
Time
12:31 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7946
Sewer Name
MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_844699_TV05336_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
8 in.
Upstream MH
05 1384
Downstream MH
05 1385
Dir. of Survey
Upstream
Length Surveyed
315.5 ft.
Total Length
315.5 ft.
Structural Index
4
Structural Quick
4K00
Structural Rating
248
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
250
Pipe schematic from manhole 05 1384 to 05 1385
MH: 05 1384MH: 05 1385upstream0 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 05 13851.8 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish40.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"192.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"235.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"254.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES313.4 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start315.5 ft. MWL - Water Level, 10 %of cross sectional area315.5 ft. MWM - Water Mark, 20 %of cross sectional area315.5 ft. AMH - Downstream Manhole, Survey Begins - 05 1384

Observation photos (1)

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
60.9TFA
313.7FM
0MWL
0MWM
60DAGS
231TFC
123.2TF
315.5MGOCONNECTION IN MH, 3 O' CLOCK
275.3TFC
0AMH05 1384
315.5AMH05 1385
80TFC
2.1FM

Properties (7)

additional_info
SC411808
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-08-11T00:31:36-07:00
documentation
PROPIPE
is_lateral_inspection
false