Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 12, 2020, 07:51 AM
  • 05 1295_05 1378_08122020_005623.mp4

Date
08/12/2020
W/O
844699
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06598
Time
12:51 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7948
Sewer Name
MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_844699_TV05336_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1378
Downstream MH
05 1295
Dir. of Survey
Upstream
Length Surveyed
33.3 ft.
Total Length
33.3 ft.
Structural Index
3
Structural Quick
4526
Structural Rating
32
O&M Index
2
O&M Quick
2600
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
44
Pipe schematic from manhole 05 1378 to 05 1295
MH: 05 1378MH: 05 1295upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 12950 ft. MGO - General Observation - CONN @ MH 9 O' CLOCK/0 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish25.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start31.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start33.3 ft. AMH - Downstream Manhole, Survey Begins - 05 137833.3 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/ACTIVE33.3 ft. MGO - General Observation - CONN @ MH 9 O' CLOCK/ACTIVE33.3 ft. MWL - Water Level, 20 %of cross sectional area33.3 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
33.3AMH05 1295
33.3MGOCONN @ MH 9 O' CLOCK/
2DAGS
33.3FM
0AMH05 1378
31DAGS
0MGOCONN @ MH 3 O' CLOCK/ACTIVE
0MGOCONN @ MH 9 O' CLOCK/ACTIVE
0MWL
31SSS
0MWM
7.9FM
2SSS

Properties (7)

additional_info
SC411809
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2020-08-12T00:51:28-07:00
documentation
PROPIPE
is_lateral_inspection
false