- Date
- 08/13/2020
- W/O
- 844360
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00306
- PipeID
- P03611
- Time
- 10:02 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7955
- Sewer Name
- TELEGRAPH ROAD TRUNK
- City
- COMMERCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_844360_TV02116_AUG2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 24 in.
- Upstream MH
- 02 1039
- Downstream MH
- 02 1040
- Dir. of Survey
- Upstream
- Length Surveyed
- 298 ft.
- Total Length
- 298 ft.
- Structural Index
- 3
- Structural Quick
- 3K2K
- Structural Rating
- 295
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 118
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 413
Pipe schematic from manhole 02 1039 to 02 1040 Observation photos (7)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

9.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

297.2 ft. - Repair Other, within 8 inches of joint: YES - LINK PIPE

298 ft. - Repair Other Defective, within 8 inches of joint: YES - LINK PIPE

298 ft. - Survey Abandoned - REVERSAL COMPLETE. DEFECTIVE LINK PIPE.