Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2020, 06:04 AM
  • 29 0529_29 0515_07132020_231744.mp4

Date
07/13/2020
W/O
839468
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01106
PipeID
P24583
Time
11:04 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7914
Sewer Name
19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_839468_TV29072_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0529
Downstream MH
29 0515
Dir. of Survey
Downstream
Length Surveyed
326.6 ft.
Total Length
326.6 ft.
Structural Index
2
Structural Quick
3C2L
Structural Rating
182
O&M Index
2
O&M Quick
2L00
O&M Rating
128
Overall Index
2
Overall Quick
Overall Rating
310
Pipe schematic from manhole 29 0529 to 29 0515
MH: 29 0529MH: 29 0515downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 05292 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start19.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN50 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN103.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6"104.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish107.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6", 6" - OPEN109.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN204.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6"206.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"257.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"297.8 ft. CM - Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES324 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish326 ft. MGO - General Observation - ROACHES @ MH326.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE326.6 ft. AMH - Downstream Manhole, Survey Ends - 29 0515

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    19.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

    297.8 ft. - Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
2SSS
109.2TFOPEN
326.6MGOCONN @ MH 9 O'CLOCK/ACTIVE
297.8CM
204.7TFA
0MWM
2DAGS
0MWL
104.5CM
324SSS
107.2TFOPEN
324DAGS
26.4TFOPEN
326.6AMH29 0515
0AMH29 0529
257.1TFC
50TFOPEN
19.6CM
206.1TFA
326MGOROACHES @ MH
103.6TFA

Properties (7)

additional_info
SC411773
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-07-13T23:04:15-07:00
documentation
PROPIPE
is_lateral_inspection
false