C 0100_C 0099_912020_014737.mp4
2 ft. - General Observation - MAG COAT 98% START 10:00 TO 2:00
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
150.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE UNDER MAG COAT
248.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE CONCRETE
259 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
500.5 ft. - General Observation - RAISED BUILT CONCRETE STRIP AT 12:00 START
501.6 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG UNDER MAG COAT
521 ft. - Surface Aggregate Missing, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG
525.3 ft. - General Observation - RAISED CONCRETE AT 12:00 FALLING APART UNDER MAG COAT
525.9 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
553.3 ft. - Surface Aggregate Missing, at 12 o'clock, within 8 inches of joint: NO - RAISED CONCRETE AREA
561.4 ft. - Surface Aggregate Missing, from 12 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
648.5 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG
736.4 ft. - Surface Aggregate Missing, from 10 to 12 o'clock, within 8 inches of joint: NO - SEVERE AGG
767.9 ft. - Surface Aggregate Missing, at 12 o'clock, within 8 inches of joint: NO - CENTER RAISED CONCRETE SECTION BROKEN AWAY
773.4 ft. - General Photograph - MISSING RAISED CONCRETE SECTION
910.6 ft. - General Observation - 30LBS DEBRIE ON CABLE
| Distance | Code | Observation |
|---|---|---|
| 561.4 | SAM | SEVERE AGG |
| 910.5 | SAP | SEVERE AGG |
| 910.9 | AMH | 3:55AM |
| 525.3 | MGO | RAISED CONCRETE AT 12:00 FALLING APART UNDER MAG COAT |
| 2 | MGO | MAG COAT 98% START 10:00 TO 2:00 |
| 910.6 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 910.6 | SAM | SEVERE AGG |
| 736.4 | SAM | SEVERE AGG |
| 259 | DAGS | — |
| 501.6 | SAP | SEVERE AGG UNDER MAG COAT |
| 525.9 | SAM | SEVERE AGG |
| 150.1 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 0 | MWM | — |
| 248.3 | SSS | BLISTERING PEELING CONCRETE CONCRETE |
| 494.9 | TFC | Capped |
| 910.6 | DAGS | — |
| 773.4 | MGP | MISSING RAISED CONCRETE SECTION |
| 910.6 | MGO | 30LBS DEBRIE ON CABLE |
| 0 | MWL | — |
| 2 | SAM | SEVERE AGG |
| 648.5 | SAM | SEVERE AGG |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 521 | SAM | SEVERE AGG |
| 553.3 | SAM | RAISED CONCRETE AREA |
| 500.5 | MGO | RAISED BUILT CONCRETE STRIP AT 12:00 START |
| 767.9 | SAM | CENTER RAISED CONCRETE SECTION BROKEN AWAY |
| 0 | AMH | 2:20AM |