Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2020, 04:31 AM
  • 29 0519_29 0518A_07132020_213706.mp4

Date
07/13/2020
W/O
839467
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01106
PipeID
P24570
Time
9:31 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7913
Sewer Name
19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_839467_TV29004_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0519
Downstream MH
29 0518A
Dir. of Survey
Downstream
Length Surveyed
101.8 ft.
Total Length
101.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 29 0519 to 29 0518A
MH: 29 0519MH: 29 0518Adownstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 05190 ft. MWL - Water Level, 5 %of cross sectional area2.1 ft. MGO - General Observation - PIPE IS LINED14.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"46.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"66.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"91 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"101.8 ft. ACOM - Cleanout Mainline, Survey Ends - 29 0518A

Observations (9)

DistanceCodeObservation
2.1MGOPIPE IS LINED
46.3TF
66.9TF
14.9TFA
0MWM
91TF
101.8ACOM29 0518A
0AMH29 0519
0MWL

Properties (8)

additional_info
SC411772
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2020-07-13T21:31:16-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP