Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2020, 05:03 AM
  • B 0730_B 0729_07132020_223140.mp4

Date
07/13/2020
W/O
839013
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00111
PipeID
P09194
Time
10:03 PM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7876
Sewer Name
JOINT OUTFALL B - UNIT 8H
City
DUARTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_839013_TV22165_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
21 in.
Upstream MH
B 0730
Downstream MH
B 0729
Dir. of Survey
Downstream
Length Surveyed
346.6 ft.
Total Length
346.6 ft.
Structural Index
3
Structural Quick
413M
Structural Rating
208
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
3
Overall Quick
Overall Rating
344
Pipe schematic from manhole B 0730 to B 0729
MH: B 0730MH: B 0729downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 07300 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start37 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"88.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"94.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"97.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"193.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"208.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"230.7 ft. FM - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES284.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"295.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"343.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish343.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish346.6 ft. MGO - General Observation - CONNECTION IN MH, 9 O' CLOCK346.6 ft. AMH - Downstream Manhole, Survey Ends - B 0729346.6 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK346.6 ft. MGO - General Observation - COCKROACHES AT MH

Observation photos (5)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

    230.7 ft. - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES AT MH

    346.6 ft. - General Observation - COCKROACHES AT MH

Observations (22)

DistanceCodeObservation
97.2TFC
0AMHB 0730
0MWM
4.7CM
346.6MGOCONNECTION IN MH, 9 O' CLOCK
37TFA
346.6AMHB 0729
284.5TFC
346.6MGOCONNECTION IN MH, 3 O' CLOCK
208.4TFA
0MGOCOCKROACHES IN MH
230.7FM
343.4CM
295.5TBA
94.4TFA
0MWL
346.6MGOCOCKROACHES AT MH
343.4DAGS
0MGOCONNECTION IN MH, 3 O' CLOCK
88.7TF
193.9TFC
2DAGS

Properties (7)

additional_info
SC411715
custom_field_three
MULTIPLE CRACKS/FRACTURES
custom_field_two
2
customer
1
datetime
2020-07-13T22:03:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false