Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2020, 11:03 AM
  • 08 0231_08 0230 _07132020_043101.mp4

Date
07/13/2020
W/O
839004
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00005
PipeID
P00105
Time
4:03 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7912
Sewer Name
EAST ROAD TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_839004_TV08112_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
12 in.
Upstream MH
08 0230
Downstream MH
08 0231
Dir. of Survey
Upstream
Length Surveyed
347.3 ft.
Total Length
347.3 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 08 0230 to 08 0231
MH: 08 0230MH: 08 0231upstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 08 02310 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish74 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"75.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"133.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"237.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"332 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"344.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start347.3 ft. MWM - Water Mark, 25 %of cross sectional area347.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK347.3 ft. MWL - Water Level, 10 %of cross sectional area347.3 ft. AMH - Downstream Manhole, Survey Begins - 08 0230

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    273.3 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (14)

DistanceCodeObservation
0MWM
273.3TB
110.1TF
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
0AMH08 0230
347.3MGOCONNECTION AT MH 3 O'CLOCK
2.6FM
271.7TFC
347.2FM
347.3AMH08 0231
213.7TFA
15.3TF
347.3MGOCONNECTION AT MH 9 O'CLOCK

Properties (7)

additional_info
SC411771
custom_field_three
MULTIPLE CRACKS/ FRACTURE'S
custom_field_two
2
customer
1
datetime
2020-07-13T04:03:15-07:00
documentation
PROPIPE
is_lateral_inspection
false