Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2020, 07:17 AM
  • 08 0217_08 0216 _07102020_003748.mp4

Date
07/10/2020
W/O
839004
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00005
PipeID
P00087
Time
12:17 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7911
Sewer Name
EAST ROAD TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_839004_TV08112_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0217
Downstream MH
08 0216
Dir. of Survey
Downstream
Length Surveyed
349.6 ft.
Total Length
349.6 ft.
Structural Index
4
Structural Quick
4M22
Structural Rating
280
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
280
Pipe schematic from manhole 08 0217 to 08 0216
MH: 08 0217MH: 08 0216downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 02170 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - POSSIBLE DEFECTIVE VCP4.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start345 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish349.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish349.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED349.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0216349.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0AMH08 0217
349.6MGOCONNECTION AT MH 3 O'CLOCK CAPPED
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
345SSS
349.6AMH08 0216
349.5FM
349.6MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0MWL
0MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0MWM
4.8FM
2SSSPOSSIBLE DEFECTIVE VCP

Properties (7)

additional_info
SC411770
custom_field_three
POSSIBLE DEFECTIVE VCP
custom_field_two
2
customer
1
datetime
2020-07-10T00:17:46-07:00
documentation
PROPIPE
is_lateral_inspection
false