Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2020, 07:06 AM
  • 08 0608_08 0607_07092020_001306.mp4

Date
07/09/2020
W/O
839310
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00011
PipeID
P00646
Time
12:06 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7907
Sewer Name
JAMES STREET RELIEF TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
WO_839310_TV08147_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
30 in.
Upstream MH
08 0608
Downstream MH
08 0607
Dir. of Survey
Downstream
Length Surveyed
142.9 ft.
Total Length
142.9 ft.
Structural Index
2
Structural Quick
3E2E
Structural Rating
142
O&M Index
2
O&M Quick
2E00
O&M Rating
56
Overall Index
2
Overall Quick
Overall Rating
198
Pipe schematic from manhole 08 0608 to 08 0607
MH: 08 0608MH: 08 0607downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 06080 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.6 ft. FC - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES140 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish140 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish140 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish142.9 ft. AMH - Downstream Manhole, Survey Ends - 08 0607142.9 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN

Observation photos (1)

  • Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES

    8.6 ft. - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
2SSS
8.6FC
0AMH08 0608
0MWM
142.9AMH08 0607
140CM
140SSS
140DAGS
2CM
142.9MGOCONN @ MH 9 O'CLOCK/UNKNOWN
0MWL
2DAGS

Properties (8)

additional_info
SC411765
custom_field_three
NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2020-07-09T00:06:31-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
30711