Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2020, 07:51 AM
  • 01 0952_01 0951_07092020_010453.mp4

Date
07/09/2020
W/O
839465
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00228
PipeID
P01789
Time
12:51 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7824
Sewer Name
WRIGHT ROAD TRUNK
City
BELL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
WO_839465_TV01076_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
36 in.
Upstream MH
01 0952
Downstream MH
01 0951
Dir. of Survey
Downstream
Length Surveyed
301.6 ft.
Total Length
301.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412O
O&M Rating
164
Overall Index
2
Overall Quick
Overall Rating
164
Pipe schematic from manhole 01 0952 to 01 0951
MH: 01 0952MH: 01 0951downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 09523.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start3.5 ft. MGO - General Observation - LINED PIPE196.7 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start299.8 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish299.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish301.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0951

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    3.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0MWL
3.5DAGS
0MWM
301.6AMH01 0951
3.5MGOLINED PIPE
0AMH01 0952
299.8DSC
299.8DAGS
196.7DSC

Properties (8)

additional_info
SC411634
custom_field_three
LINED PIPE, NO STRUCTURAL DEFECTS
custom_field_two
4
customer
1
datetime
2020-07-09T00:51:10-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP