Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 17, 2020, 05:58 AM
  • H 0386_H 0385_07162020_235737.mp4

Date
07/16/2020
W/O
838814
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00177
PipeID
P10815
Time
10:58 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7924
Sewer Name
JOINT OUTFALL H - UNIT 5A
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_838814_TV15130_JUL2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Width
60 in.
Upstream MH
H 0386
Downstream MH
H 0385
Dir. of Survey
Downstream
Length Surveyed
470.3 ft.
Total Length
470.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole H 0386 to H 0385
MH: H 0386MH: H 0385downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 03860 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT470.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish470.3 ft. AMH - Downstream Manhole, Survey Ends - H 0385

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMHH 0386
0MWM
2.1SAV
470.3SAV
2.1MGOMAG COAT
0MWL
470.3AMHH 0385

Properties (7)

additional_info
SC411783
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2020-07-16T22:58:38-07:00
documentation
PROPIPE
is_lateral_inspection
false