Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 15, 2020, 09:02 AM
  • 03 0145_03 0144_07152020_021539.mp4

Date
07/15/2020
W/O
838910
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00363
PipeID
P04761
Time
2:02 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7919
Sewer Name
LAKEWOOD TRUNK
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_838910_TV03169_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
24 in.
Upstream MH
03 0144
Downstream MH
03 0145
Dir. of Survey
Upstream
Length Surveyed
289.7 ft.
Total Length
289.7 ft.
Structural Index
3
Structural Quick
413J
Structural Rating
172
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
172
Pipe schematic from manhole 03 0144 to 03 0145
MH: 03 0144MH: 03 0145upstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 03 01456.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES6.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish154.2 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"247.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE286 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start287.7 ft. MGO - General Observation - ROUGH / "SPOTTY" SURFACE - 8 TO 4 O'CLOCK - THROUGHOUT LINE - VCP289.7 ft. AMH - Downstream Manhole, Survey Begins - 03 0144289.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK289.7 ft. MWM - Water Mark, 30 %of cross sectional area289.7 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE

    42.2 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - APPARENTLY ACTIVE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    283.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
0AMH03 0144
42.2TBAPPARENTLY ACTIVE
135.5TFA
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
283.4FM
0MWM
3.7CM
0MWL
2MGOROUGH / "SPOTTY" SURFACE - 8 TO 4 O'CLOCK - THROUGHOUT LINE - VCP
289.7MGOACTIVE CONNECTION AT MH 3 O'CLOCK
283.4CM
289.7AMH03 0145

Properties (7)

additional_info
SC411778
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-07-15T02:02:11-07:00
documentation
PROPIPE
is_lateral_inspection
false