Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2020, 10:16 AM
  • 32 0069_32 0068 _07092020_032608.mp4

Date
07/09/2020
W/O
838999
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19833
Time
3:16 AM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7872
Sewer Name
CASTAIC TRUNK
City
CASTAIC
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
01
Purpose
Routine Assessment
Project
WO_838999_TV32047_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0069
Downstream MH
32 0068
Dir. of Survey
Downstream
Length Surveyed
193 ft.
Total Length
193 ft.
Structural Index
4
Structural Quick
4231
Structural Rating
11
O&M Index
2
O&M Quick
2G00
O&M Rating
76
Overall Index
2
Overall Quick
Overall Rating
87
Pipe schematic from manhole 32 0069 to 32 0068
MH: 32 0069MH: 32 0068downstream0 ft. MGO - General Observation - POSSIBLE CONNECTION (& ACTIVE) @ U/S MH - 3 O'CLK.0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 00692 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start69.7 ft. FM - Fracture Multiple, from 06 to 02 o'clock, within 8 inches of joint: YES96.5 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES, Start102.8 ft. RPL - Repair Localized Liner, within 8 inches of joint: YES, Finish117.5 ft. FS - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES148.5 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES191.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish191.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE193 ft. AMH - Downstream Manhole, Survey Ends - 32 0068

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 06 to 02 o'clock, within 8 inches of joint: YES

    69.7 ft. - Fracture Multiple, from 06 to 02 o'clock, within 8 inches of joint: YES

  • Repair Localized Liner, within 8 inches of joint: YES, Start

    96.5 ft. - Repair Localized Liner, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

    117.5 ft. - Fracture Spiral, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    148.5 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    191.2 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
2DAGS
193AMH32 0068
69.7FM
191.2DAGS
191.2MGOCOCKROACHES IN MANHOLE
0MGOPOSSIBLE CONNECTION (& ACTIVE) @ U/S MH - 3 O'CLK.
102.8RPL
0MWL
96.5RPL
117.5FS
148.5FM
0MWM
0AMH32 0069

Properties (8)

additional_info
SC411711
custom_field_three
FRACTURES
custom_field_two
2
customer
1
datetime
2020-07-09T03:16:06-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27282