Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 25, 2020, 11:46 AM
  • F 0027_F 0026_8252020_044724.mp4

Date
08/25/2020
W/O
0838961
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00033
PipeID
P10117
Time
4:46 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1546
Sewer Name
F JOINT OUTFALL F - UNIT 1
City
PARAMOUNT
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
20200825MDM_JOINT_OUTFALL_F_UNIT_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
69 in.
Upstream MH
F 0027
Downstream MH
F 0026
Dir. of Survey
Downstream
Length Surveyed
536.9 ft.
Total Length
536.9 ft.
Structural Index
5
Structural Quick
5441
Structural Rating
24
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
28
Pipe schematic from manhole F 0027 to F 0026
MH: F 0027MH: F 0026downstream0 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM89.8 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR MISSING103.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - BROKEN REBAR246.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR536.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR536.2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish - LONG CIRCUM REBAR BROKEN MISSING536.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active536.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG536.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN536.9 ft. AMH - Downstream Manhole, Survey Ends - 5:05AM

Observation photos (5)

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    0 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

    0 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR MISSING

    89.8 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR MISSING

  • Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - BROKEN REBAR

    103.7 ft. - Surface Reinforcement Corroded, from 10 to 12 o'clock, within 8 inches of joint: NO - BROKEN REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    246.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

Observations (14)

DistanceCodeObservation
0SAMSEVERE AGG
0MWM
89.8SRCLONG CIRCUM REBAR MISSING
536.2SRCLONG CIRCUM REBAR
536.2SRCLONG CIRCUM REBAR BROKEN MISSING
0SRCLONG & CIRCUM REBAR
536.2MGOConn. @ Mh, 3 O' Clock. Active
536.2SAMSEVERE AGG
536.9AMH5:05AM
0MWL
536.2MGOConn. @ Mh, 9 O' Clock. OPEN
103.7SRCBROKEN REBAR
0AMH4:50AM
246.2SRCLONG CIRCUM REBAR

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED BROKEN MISSING
custom_field_two
1
customer
LACSD
datetime
2020-08-25T04:46:06-07:00
documentation
MARTIN,OLIVER 111,BARR,CASTILLO
is_lateral_inspection
false