Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2020, 10:40 AM
  • B 1184_B 1183 _07012020_035228.mp4

Date
07/01/2020
W/O
839010
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01125
PipeID
P13504
Time
3:40 AM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7863
Sewer Name
JOINT OUTFALL B - UNIT 6H
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_839010_TV16118_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
B 1184
Downstream MH
B 1183
Dir. of Survey
Downstream
Length Surveyed
259.5 ft.
Total Length
259.5 ft.
Structural Index
3
Structural Quick
5132
Structural Rating
13
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole B 1184 to B 1183
MH: B 1184MH: B 1183downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 11840 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start24.1 ft. HSV - Hole Soil Visible, at 02 o'clock, within 8 inches of joint: YES - EXISTING HOLE49.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start170.1 ft. FS - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES170.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish242.2 ft. CS - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES257.7 ft. MGO - General Observation - ROACHES IN MH257.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish259.5 ft. AMH - Downstream Manhole, Survey Ends - B 1183

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Hole Soil Visible, at 02 o'clock, within 8 inches of joint: YES - EXISTING HOLE

    24.1 ft. - Hole Soil Visible, at 02 o'clock, within 8 inches of joint: YES - EXISTING HOLE

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    49.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    170.1 ft. - Fracture Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    242.2 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

  • General Observation - ROACHES IN MH

    257.7 ft. - General Observation - ROACHES IN MH

Observations (12)

DistanceCodeObservation
0MWL
49.8CM
24.1HSVEXISTING HOLE
257.7MGOROACHES IN MH
257.7DAGS
170.1FS
0AMHB 1184
2DAGS
242.2CS
0MWM
259.5AMHB 1183
170.1CM

Properties (7)

additional_info
SC411701
custom_field_three
CRACKS/FRACTURES/EXISTING HOLE
custom_field_two
2
customer
1
datetime
2020-07-01T03:40:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false