Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2020, 05:01 AM
  • 18 0167_18 0166_07282020_221228.mp4

Date
07/28/2020
W/O
838905
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P13990
Time
10:01 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7932
Sewer Name
ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_838905_TV18135_JUL2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
18 0166
Downstream MH
18 0167
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 18 0166 to 18 0167
MH: 18 0166MH: 18 0167upstream0 ft. SAP - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - UP LEG SIPHON FRON DN STREAM MH0 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO1.7 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. MWL - Water Level, 25 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - 18 0166

Observation photos (3)

  • Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Projecting, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - UP LEG SIPHON FRON DN STREAM MH

    2.1 ft. - Survey Abandoned - UP LEG SIPHON FRON DN STREAM MH

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    2.1 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

Observations (6)

DistanceCodeObservation
2.1SAP
2.1MSAUP LEG SIPHON FRON DN STREAM MH
0MWL
0.4MWM
0AMH18 0166
2.1SRV

Properties (7)

additional_info
SC411792
custom_field_three
REINFORCEMENT VISIBLE/AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2020-07-28T22:01:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false