Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2020, 05:32 AM
  • 18 0189_18 0188_07282020_230128.mp4

Date
07/28/2020
W/O
838905
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P14014
Time
10:32 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7932
Sewer Name
ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_838905_TV18135_JUL2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
18 0189
Downstream MH
18 0188
Dir. of Survey
Downstream
Length Surveyed
553.8 ft.
Total Length
553.8 ft.
Structural Index
3
Structural Quick
3U2U
Structural Rating
550
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
550
Pipe schematic from manhole 18 0189 to 18 0188
MH: 18 0189MH: 18 0188downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 01892.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start169.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"269.1 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"553.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish553.8 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK553.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish553.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0188553.8 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
553.8SSS
0MWM
553.8MGOCONNECTION AT MH 9 OCLOCK
553.8SAV
553.8AMH18 0188
2.1SAV
0MWL
269.1TFA
0MGOCONNECTION AT MH 3 OCLOCK
0AMH18 0189
553.8MGOCONNECTION AT MH 3 OCLOCK
2.1SSS
169.4TB

Properties (7)

additional_info
SC411792
custom_field_three
AGGREGATE VISIBLE/ SPALLING
custom_field_two
3
customer
1
datetime
2020-07-28T22:32:44-07:00
documentation
PRO PIPE
is_lateral_inspection
false