Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2020, 08:40 AM
  • G 0328_G 0327_07102020_014754.mp4

Date
07/10/2020
W/O
838752
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01247
PipeID
P01764
Time
1:40 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7827
Sewer Name
G JOINT OUTFALL G - UNIT 9 TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_838752_TV01202_JUL2020
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
30 in.
Width
39 in.
Upstream MH
G 0327
Downstream MH
G 0328
Dir. of Survey
Upstream
Length Surveyed
77.6 ft.
Total Length
77.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
312B
O&M Rating
33
Overall Index
2
Overall Quick
Overall Rating
36
Pipe schematic from manhole G 0327 to G 0328
MH: G 0327MH: G 0328upstream0 ft. MSA - Survey Abandoned - REVERSAL COMPLETED0 ft. OBP - Obstacles External Pipe or Cable, 15 %of cross sectional area, from 04 to 07 o'clock0 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish75.1 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start75.1 ft. MGO - General Observation - MAG COATING ATTATCHED75.1 ft. CM - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: NO77.6 ft. MWL - Water Level, 10 %of cross sectional area77.6 ft. MWM - Water Mark, 15 %of cross sectional area77.6 ft. AMH - Downstream Manhole, Survey Begins - G 0327

Observation photos (3)

  • Deposits Settled Compacted,  10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.5 ft. - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: NO

    2.5 ft. - Crack Multiple, from 09 to 10 o'clock, within 8 inches of joint: NO

  • Obstacles External Pipe or Cable, 15 %of cross sectional area, from 04 to 07 o'clock

    77.6 ft. - Obstacles External Pipe or Cable, 15 %of cross sectional area, from 04 to 07 o'clock

Observations (9)

DistanceCodeObservation
2.5DSC
2.5MGOMAG COATING ATTATCHED
0MWL
0MWM
2.5CM
77.6MSAREVERSAL COMPLETED
77.6OBP
77.6DSC
0AMHG 0327

Properties (8)

additional_info
SC411637
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2020-07-10T01:40:10-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
10286