Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 13, 2020, 08:15 AM
  • G 0325_G 0324_07132020_013330.mp4

Date
07/13/2020
W/O
838752
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01247
PipeID
P01761
Time
1:15 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7828
Sewer Name
G JOINT OUTFALL G - UNIT 9 TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_838752_TV01202_JUL2020
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
30 in.
Width
39 in.
Upstream MH
G 0324
Downstream MH
G 0325
Dir. of Survey
Upstream
Length Surveyed
17.5 ft.
Total Length
17.5 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole G 0324 to G 0325
MH: G 0324MH: G 0325upstream0 ft. AMH - Upstream Manhole, Survey Ends - G 03250 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0.6 ft. SZ - Surface Other, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - MISSING TILES0.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish9 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - POSSIBLY TILES14.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start15.5 ft. SZ - Surface Other, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MISSING TILES17.5 ft. MWM - Water Mark, 55 %of cross sectional area17.5 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK17.5 ft. MWL - Water Level, 40 %of cross sectional area17.5 ft. AMH - Downstream Manhole, Survey Begins - G 0324

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
17.5AMHG 0325
16.9SZMISSING TILES
17.5MGOCONNECTION AT MH, 9 O'CLOCK
0MWM
8.5DSCPOSSIBLY TILES
2SZMISSING TILES
0MGOCONNECTION AT MH, 3 O'CLOCK
0MWL
3SAP
17.5MGOCONNECTION AT MH, 3 O'CLOCK
0AMHG 0324
16.9SAP

Properties (8)

additional_info
SC411638
custom_field_three
MISSING TILES, AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2020-07-13T01:15:35-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
10286