Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 15, 2020, 06:39 AM
  • 08 0141A_08 0141_07142020_235607.mp4

Date
07/14/2020
W/O
839002
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00006
PipeID
P00198
Time
11:39 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7917
Sewer Name
FIGUEROA STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_839002_TV08002_JUL2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
8 in.
Upstream MH
08 0141A
Downstream MH
08 0141
Dir. of Survey
Downstream
Length Surveyed
231 ft.
Total Length
231 ft.
Structural Index
3
Structural Quick
413H
Structural Rating
142
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
142
Pipe schematic from manhole 08 0141A to 08 0141
MH: 08 0141AMH: 08 0141downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 08 0141A0 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start6.1 ft. FM - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES57 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN - PASSED-BY156.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"231 ft. SAP - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish231 ft. AMH - Downstream Manhole, Survey Ends - 08 0141

Observation photos (2)

  • Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

    6.1 ft. - Fracture Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
0MWM
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
231SAP
0AMH08 0141A
156.7TFC
2.1SAP
231AMH08 0141
0MWL
6.1FM
57TFUNKNOWN - PASSED-BY

Properties (7)

additional_info
SC411776
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2020-07-14T23:39:18-07:00
documentation
PROPIPE
is_lateral_inspection
false