Wastewater/Activity/PacpInspection/1.0Jul 8, 2020, 08:41 AM
- Date
- 07/08/2020
- W/O
- 833715
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00581
- PipeID
- P26778
- Time
- 1:41 AM
- Certificate
- U-111-11880
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7870
- Sewer Name
- TRUNK "E"
- City
- LANCASTER
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- District
- District 14
- Page No.
- 17
- Purpose
- Routine Assessment
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Other
- Height
- 15 in.
- Upstream MH
- 14 0388
- Downstream MH
- 14 0387A
- Dir. of Survey
- Downstream
- Length Surveyed
- 274.3 ft.
- Total Length
- 274.3 ft.
- Structural Index
- 2
- Structural Quick
- 322J
- Structural Rating
- 114
- O&M Index
- 2
- O&M Quick
- 412J
- O&M Rating
- 116
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 230
Pipe schematic from manhole 14 0388 to 14 0387A Observation photos (4)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

274.3 ft. - General Observation - ROACHES @ MH
Observations (26)
| Distance | Code | Observation |
|---|
| 124.6 | TFA | — |
| 272.8 | SSS | — |
| 2 | SSS | — |
| 2 | MGO | 40% MAG COAT |
| 197 | TF | UNKNOWN |
| 76.6 | TF | OPEN |
| 56 | TFC | — |
| 0 | MWL | — |
| 27.8 | TFA | — |
| 274.3 | MGO | CONN @ MH 9 O'CLOCK/ACTIVE |
| 0 | AMH | 14 0388 |
| 274.3 | AMH | 14 0387A |
| 2 | DAGS | — |
| 105.5 | TFC | — |
| 196.9 | TFC | — |
| 2 | DAR | — |
| 272.8 | SAP | — |
| 257.7 | TFC | — |
| 2 | SAP | — |
| 0 | MWM | — |
| 233.5 | TFC | — |
| 272.8 | DAGS | — |
| 272 | DAR | — |
| 149.1 | TFC | — |
| 274.3 | MGO | ROACHES @ MH |
| 176.6 | TFC | — |
Properties (7)
- additional_info
- SC411709
- custom_field_three
- SPALLING/PROJECTING AGGREGATE
- custom_field_two
- 2
- customer
- 1
- datetime
- 2020-07-08T01:41:14-07:00
- documentation
- PRO PIPE
- is_lateral_inspection
- false