Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2020, 08:49 AM
  • B 0360_B 0359_07302020_020215.mp4

Date
07/30/2020
W/O
839230
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00091
PipeID
P08872
Time
1:49 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7892
Sewer Name
JOINT OUTFALL B - UNIT 5A
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
10
Purpose
Routine Assessment
Project
WO_839230_TV15051_JUL2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
63 in.
Upstream MH
B 0360
Downstream MH
B 0359
Dir. of Survey
Downstream
Length Surveyed
269 ft.
Total Length
269 ft.
Structural Index
3
Structural Quick
3I2J
Structural Rating
262
O&M Index
2
O&M Quick
2J00
O&M Rating
106
Overall Index
2
Overall Quick
Overall Rating
368
Pipe schematic from manhole B 0360 to B 0359
MH: B 0360MH: B 0359downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 03600 ft. MGO - General Observation - ABANDONED MH0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 55% MAG COAT2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start7.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start266 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish266.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish266.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish268 ft. MGO - General Observation - CONN @ MH 3 O' CLOCK/CAPPED269 ft. AMH - Downstream Manhole, Survey Ends - B 0359269 ft. MGO - General Observation - ROACHES @ MH

Observation photos (4)

  • General Observation - ABANDONED MH

    0 ft. - General Observation - ABANDONED MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    7.2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    269 ft. - General Observation - ROACHES @ MH

Observations (14)

DistanceCodeObservation
269AMHB 0359
2SSS
0AMHB 0360
7.2SAP
2MGO55% MAG COAT
268MGOCONN @ MH 3 O' CLOCK/CAPPED
0MGOABANDONED MH
266.8SAP
2DAGS
266SSS
269MGOROACHES @ MH
0MWM
266.8DAGS
0MWL

Properties (7)

additional_info
SC411732
custom_field_three
SPALLING/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2020-07-30T01:49:43-07:00
documentation
PRO PIPE
is_lateral_inspection
false