Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2020, 05:31 AM
  • 15 0723_15 0722_06222020_225134.mp4

Date
06/22/2020
W/O
833716
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00616
PipeID
P12616
Time
10:31 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7804
Sewer Name
15 MONROVIA OUTFALL TRUNK
City
MONROVIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
Routine Assessment
Project
WO_833716_TV15131_JUN2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
15 0723
Downstream MH
15 0722
Dir. of Survey
Downstream
Length Surveyed
54.1 ft.
Total Length
54.1 ft.
Structural Index
3
Structural Quick
3A00
Structural Rating
30
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 15 0723 to 15 0722
MH: 15 0723MH: 15 0722downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07230 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK - FLOW STATUS UNKNOWN0 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. MGO - General Observation - COCKROACHES THROUGHOUT SEWER LINE2.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. MGO - General Observation - MAG COATING ATTATCHED16.4 ft. TB - Active Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.9 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 4" - 2 CONNS. PRESENT - SAME SIZE - UNKNOWN FLOW STATUS54.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish54.1 ft. AMH - Downstream Manhole, Survey Ends - 15 072254.1 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 8" - UNKNOWN FLOW STATUS

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
54.1SAP
54.1AMH15 0722
0MWL
2.7SAP
16.4TB
0AMH15 0723
0MGOCONNECTION IN MH, 3 O' CLOCK - FLOW STATUS UNKNOWN
2.7MGOMAG COATING ATTATCHED
54.1TBUNKNOWN FLOW STATUS
53.9TB2 CONNS. PRESENT - SAME SIZE - UNKNOWN FLOW STATUS
0MWM
2MGOCOCKROACHES THROUGHOUT SEWER LINE

Properties (7)

additional_info
SC411614
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2020-06-22T22:31:54-07:00
documentation
PROPIPE
is_lateral_inspection
false