- Date
- 07/10/2020
- W/O
- 0842588
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00225
- PipeID
- P02181
- Time
- 12:27 PM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Jetting
- Media Label
- G8302
- Sewer Name
- 01 WILCOX AVENUE TRUNK
- City
- SOUTH GATE
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 11
- Purpose
- Maintenance Related
- Project
- 20200710DF_WILCOX_AVENUE_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 01 1150
- Downstream MH
- H 0077
- Dir. of Survey
- Downstream
- Length Surveyed
- 424.5 ft.
- Total Length
- 424.5 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 01 1150 to H 0077 Observation photos (3)

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - General Observation - 70% MAG COAT

261.6 ft. - Water Level, 40 %of cross sectional area