Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2020, 07:27 PM
  • 01 1150_H 0077_7102020_125004.avi

Date
07/10/2020
W/O
0842588
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00225
PipeID
P02181
Time
12:27 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G8302
Sewer Name
01 WILCOX AVENUE TRUNK
City
SOUTH GATE
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Maintenance Related
Project
20200710DF_WILCOX_AVENUE_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1150
Downstream MH
H 0077
Dir. of Survey
Downstream
Length Surveyed
424.5 ft.
Total Length
424.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 01 1150 to H 0077
MH: 01 1150MH: H 0077downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:44 PM0.9 ft. MWL - Water Level, 25 %of cross sectional area0.9 ft. MGO - General Observation - ROACHES @ MH0.9 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - 70% MAG COAT186.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"261.6 ft. MWL - Water Level, 40 %of cross sectional area315.3 ft. MWL - Water Level, 70 %of cross sectional area424.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish424.5 ft. AMH - Downstream Manhole, Survey Ends - 1:16 PM424.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 70% MAG COAT

    2.1 ft. - General Observation - 70% MAG COAT

  • Water Level, 40 %of cross sectional area

    261.6 ft. - Water Level, 40 %of cross sectional area

Observations (13)

DistanceCodeObservation
186.2TBA
0.9MWL
424.5SAV
0.9MGOROACHES @ MH
2SAV
424.5AMH1:16 PM
0AMH12:44 PM
261.6MWL
315.3MWL
424.5SSS
2.1SSS
2.1MGO70% MAG COAT
0.9MWM

Properties (6)

custom_field_two
3
customer
LACSD
datetime
2020-07-10T12:27:36-07:00
documentation
FRANKLIN, CASTILLO, RUVALCABA
is_lateral_inspection
false
year_laid
19280401