- Date
- 06/15/2020
- W/O
- 833497
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00166
- PipeID
- P10591
- Time
- 10:25 PM
- Certificate
- U-111-11880
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7697
- Sewer Name
- JOINT OUTFALL H - UNIT 1G
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_833497_TV01098_JUN2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 42 in.
- Width
- 42 in.
- Upstream MH
- H 0139
- Downstream MH
- H 0138
- Dir. of Survey
- Downstream
- Length Surveyed
- 514.7 ft.
- Total Length
- 514.7 ft.
- Structural Index
- 3
- Structural Quick
- 3S2M
- Structural Rating
- 444
- O&M Index
- 2
- O&M Quick
- 2S00
- O&M Rating
- 204
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 648
Pipe schematic from manhole H 0139 to H 0138 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

167.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

512.2 ft. - General Observation - COCKROACHES IN MANHOLE