- Date
- 06/17/2020
- W/O
- 833497
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00166
- PipeID
- P10576
- Time
- 12:03 AM
- Certificate
- U-111-11880
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7698
- Sewer Name
- JOINT OUTFALL H - UNIT 1G
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- WO_833497_TV01098_JUN2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Width
- 36 in.
- Upstream MH
- H 0124
- Downstream MH
- H 0122
- Dir. of Survey
- Downstream
- Length Surveyed
- 41.6 ft.
- Total Length
- 41.6 ft.
- Structural Index
- 3
- Structural Quick
- 3727
- Structural Rating
- 35
- O&M Index
- 2
- O&M Quick
- 2700
- O&M Rating
- 14
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 49
Pipe schematic from manhole H 0124 to H 0122 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

39 ft. - General Observation - COCKROACHES IN MANHOLE