Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 16, 2020, 04:28 AM
  • J 0014_J 0012_07152020_214943.mp4

Date
07/15/2020
W/O
839187
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00060
PipeID
P11597
Time
9:28 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7920
Sewer Name
JOINT OUTFALL J - UNIT 2A
City
HARBOR CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
33
Purpose
Routine Assessment
Project
RFIR_WO_839187_TV08171_JUL2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
J 0014
Downstream MH
J 0012
Dir. of Survey
Downstream
Length Surveyed
479.7 ft.
Total Length
479.7 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole J 0014 to J 0012
MH: J 0014MH: J 0012downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 00140 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start479.7 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish479.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK479.7 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK479.7 ft. AMH - Downstream Manhole, Survey Ends - J 0012479.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0AMHJ 0014
479.7SRV
479.7MGOACTIVE CONNECTION AT MH 3 O'CLOCK
479.7MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWL
0MWM
479.7AMHJ 0012
2.1SRV
2.1SAP
479.7SAP

Properties (7)

additional_info
SC411779
custom_field_three
AGGREGATE PROJECTING REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2020-07-15T21:28:06-07:00
documentation
PROPIPE
is_lateral_inspection
false