Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 28, 2020, 06:59 AM
  • H 0490_H 0869_07282020_001357.mp4

Date
07/27/2020
W/O
839001
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00181
PipeID
P10916
Time
11:59 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7885
Sewer Name
JOINT OUTFALL H - UNIT 6
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
RFIR_WO_839001_TV15212_JUL2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
H 0490
Downstream MH
H 0869
Dir. of Survey
Downstream
Length Surveyed
38.5 ft.
Total Length
38.5 ft.
Structural Index
4
Structural Quick
5336
Structural Rating
33
O&M Index
2
O&M Quick
2600
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
45
Pipe schematic from manhole H 0490 to H 0869
MH: H 0490MH: H 0869downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 04900 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start18.1 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start34.4 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish34.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish34.4 ft. MGO - General Observation - COCKROACHES AT MH34.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish38.5 ft. MGO - General Observation - STOP LOG CONNECTION IN MH, 3 O' CLOCK38.5 ft. AMH - Downstream Manhole, Survey Ends - H 0869

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    18.1 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES AT MH

    34.4 ft. - General Observation - COCKROACHES AT MH

Observations (12)

DistanceCodeObservation
34.4SRV
18.1SRV
34.4DAGS
0AMHH 0490
2DAGS
38.5MGOSTOP LOG CONNECTION IN MH, 3 O' CLOCK
0MWM
0MWL
34.4MGOCOCKROACHES AT MH
2SAP
38.5AMHH 0869
34.4SAP

Properties (7)

additional_info
SC411725
custom_field_three
PROJECTING AGGREGATE/VISIBLE REINFORCEMENT
custom_field_two
2
customer
1
datetime
2020-07-27T23:59:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false