Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 29, 2020, 08:21 AM
  • 18 0899_18 0898_06292020_012544.mp4

Date
06/29/2020
W/O
833718
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00709
PipeID
P14750
Time
1:21 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7810
Sewer Name
SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_833718_TV18101_JUN2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0898
Downstream MH
18 0899
Dir. of Survey
Upstream
Length Surveyed
2.4 ft.
Total Length
2.4 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole 18 0898 to 18 0899
MH: 18 0898MH: 18 0899upstream0 ft. MSA - Survey Abandoned - VIEW OF SIPHON UPLEG0 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES2.4 ft. MWL - Water Level, 20 %of cross sectional area2.4 ft. MWM - Water Mark, 25 %of cross sectional area2.4 ft. AMH - Upstream Manhole, Survey Begins - 18 0898

Observation photos (2)

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.4 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
0MWL
2.4MSAVIEW OF SIPHON UPLEG
2.4SRV
0MWM
0AMH18 0898
2.4SAP

Properties (7)

additional_info
SC411620
custom_field_three
REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2020-06-29T01:21:36-07:00
documentation
PROPIPE
is_lateral_inspection
false