- Date
- 06/30/2020
- W/O
- 833718
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00709
- PipeID
- P14711
- Time
- 12:31 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7811
- Sewer Name
- SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 34
- Purpose
- Routine Assessment
- Project
- WO_833718_TV18101_JUN2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 51 in.
- Width
- 51 in.
- Upstream MH
- 18 0856
- Downstream MH
- 18 0855
- Dir. of Survey
- Downstream
- Length Surveyed
- 733.2 ft.
- Total Length
- 733.2 ft.
- Structural Index
- 3
- Structural Quick
- 5\3\
- Structural Rating
- 1440
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 1440
Pipe schematic from manhole 18 0856 to 18 0855 Observation photos (3)

12.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

12.4 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

12.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start