- Date
- 06/24/2020
- W/O
- 833718
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00709
- PipeID
- P14703
- Time
- 11:49 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7809
- Sewer Name
- SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 37A
- Purpose
- Routine Assessment
- Project
- WO_833718_TV18101_JUN2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 51 in.
- Width
- 51 in.
- Upstream MH
- 18 0848
- Downstream MH
- 18 0847
- Dir. of Survey
- Downstream
- Length Surveyed
- 712.8 ft.
- Total Length
- 712.8 ft.
- Structural Index
- 3
- Structural Quick
- 5[3Z
- Structural Rating
- 1347
- O&M Index
- 4
- O&M Quick
- 4400
- O&M Rating
- 16
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 1363
Pipe schematic from manhole 18 0848 to 18 0847 Observation photos (3)

12.5 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

39.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

110.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start