15 0670_15 0669_06172020_232113.mp4
0 ft. - General Observation - COCKROACHES IN MH
0 ft. - General Observation - CONNECTION AT MH, 3 O'CLOCK
2.1 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start
2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start
11.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start
33.8 ft. - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"
93.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 8"
106.1 ft. - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"
| Distance | Code | Observation |
|---|---|---|
| 112.7 | MGO | COCKROACHES IN MH |
| 110.2 | SSS | — |
| 112.7 | AMH | 15 0669 |
| 0 | MGO | COCKROACHES IN MH |
| 93.4 | TB | — |
| 2.1 | SAV | — |
| 110.2 | DAGS | — |
| 106.1 | TF | — |
| 0 | MGO | CONNECTION AT MH, 3 O'CLOCK |
| 0 | MWM | — |
| 33.8 | TFC | — |
| 0 | MWL | — |
| 110.2 | SAV | — |
| 2.1 | DAGS | — |
| 0 | AMH | 15 0670 |
| 11.1 | SSS | — |