Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2020, 04:41 AM
  • 15 0664_15 0663_06302020_215753.mp4

Date
06/30/2020
W/O
833764
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00602
PipeID
P12556
Time
9:41 PM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7770
Sewer Name
EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_833764_TV15005_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0664
Downstream MH
15 0663
Dir. of Survey
Downstream
Length Surveyed
298 ft.
Total Length
298 ft.
Structural Index
3
Structural Quick
5141
Structural Rating
286
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
286
Pipe schematic from manhole 15 0664 to 15 0663
MH: 15 0664MH: 15 0663downstream0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 06640 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start32.1 ft. H - Hole, from 11 to 01 o'clock, within 8 inches of joint: NO33.7 ft. B - Broken, from 09 to 12 o'clock, within 8 inches of joint: NO42.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"44.1 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start106.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"124.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"154.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"206.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"216.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"260.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"263.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"295.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish295.3 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish298 ft. AMH - Downstream Manhole, Survey Ends - 15 0663298 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (7)

  • General Observation - CONNECTION AT MH, 3 O'CLOCK

    0 ft. - General Observation - CONNECTION AT MH, 3 O'CLOCK

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Hole, from 11 to 01 o'clock, within 8 inches of joint: NO

    32.1 ft. - Hole, from 11 to 01 o'clock, within 8 inches of joint: NO

  • Broken, from 09 to 12 o'clock, within 8 inches of joint: NO

    33.7 ft. - Broken, from 09 to 12 o'clock, within 8 inches of joint: NO

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

    44.1 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

  • General Observation - COCKROACHES IN MH

    298 ft. - General Observation - COCKROACHES IN MH

Observations (21)

DistanceCodeObservation
0MGOCONNECTION AT MH, 3 O'CLOCK
0MWL
298AMH15 0663
295.3SAP
216.7TF
33.7B
2.1SAP
298MGOCOCKROACHES IN MH
295.3SSS
44.1SSS
106.3TFC
260.6TFC
0AMH15 0664
124.6TF
206.3TFC
42.6TFC
0MWM
32.1H
0MGOCOCKROACHES IN MH
263.8TF
154.6TFC

Properties (7)

additional_info
SC427455
custom_field_three
HOLE, SURFACE AGGREGATE, SPALLING
custom_field_two
2
customer
1
datetime
2020-06-30T21:41:18-07:00
documentation
PROPIPE
is_lateral_inspection
false