Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2020, 05:00 AM
  • 15 0663_15 0662_06302020_221553.mp4

Date
06/30/2020
W/O
833764
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00602
PipeID
P12555
Time
10:00 PM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7770
Sewer Name
EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_833764_TV15005_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0663
Downstream MH
15 0662
Dir. of Survey
Downstream
Length Surveyed
300 ft.
Total Length
300 ft.
Structural Index
3
Structural Quick
3K2J
Structural Rating
285
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
285
Pipe schematic from manhole 15 0663 to 15 0662
MH: 15 0663MH: 15 0662downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 15 06632.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start11.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"25.9 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start47.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"56.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"108.4 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"132.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"162.9 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"199.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"238.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"298.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish298.2 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish300 ft. MGO - General Observation - CONNECTION AT MH, 3 AND 9 O'CLOCK300 ft. MGO - General Observation - COCKROACHES IN MH300 ft. AMH - Downstream Manhole, Survey Ends - 15 0662

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

    25.9 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

  • General Observation - COCKROACHES IN MH

    300 ft. - General Observation - COCKROACHES IN MH

Observations (19)

DistanceCodeObservation
0MWL
0MWM
0MGOCOCKROACHES IN MH
162.9TFC
0AMH15 0663
56.8TFC
300MGOCONNECTION AT MH, 3 AND 9 O'CLOCK
108.4TFC
132.9TF
25.9SSS
300MGOCOCKROACHES IN MH
199.5TF
2.1SAP
298.2SAP
47.9TF
11.3TFC
298.2SSS
300AMH15 0662
238.6TFC

Properties (7)

additional_info
SC427455
custom_field_three
SURFACE AGGREGAT, SPALLING
custom_field_two
3
customer
1
datetime
2020-06-30T22:00:52-07:00
documentation
PRO PIPE
is_lateral_inspection
false