Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2020, 05:17 AM
  • 15 0662_15 0661_06302020_224538.mp4

Date
06/30/2020
W/O
833764
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00602
PipeID
P12554
Time
10:17 PM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7770
Sewer Name
EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_833764_TV15005_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0662
Downstream MH
15 0661
Dir. of Survey
Downstream
Length Surveyed
459.6 ft.
Total Length
459.6 ft.
Structural Index
3
Structural Quick
3Q2P
Structural Rating
441
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
441
Pipe schematic from manhole 15 0662 to 15 0661
MH: 15 0662MH: 15 0661downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 06620 ft. MGO - General Observation - CONNECTION AT MH, 3 AND 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MH2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start36.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start116.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"224.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"363.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"385.6 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"456.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish456.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish459.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0661459.6 ft. MGO - General Observation - COCKROACHES IN MH459.6 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    36.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • General Observation - COCKROACHES IN MH

    459.6 ft. - General Observation - COCKROACHES IN MH

Observations (14)

DistanceCodeObservation
459.6AMH15 0661
459.6MGOCOCKROACHES IN MH
2.1SAP
456.6SAP
385.6TFC
36.3SSS
456.6SSS
0AMH15 0662
0MGOCONNECTION AT MH, 3 AND 9 O'CLOCK
459.6MGOCONNECTION AT MH, 3 O'CLOCK
116.3TF
363.7TF
224.9TF
0MGOCOCKROACHES IN MH

Properties (7)

additional_info
SC427455
custom_field_three
SURFACE AGGREGATE, SPALLING
custom_field_two
3
customer
1
datetime
2020-06-30T22:17:56-07:00
documentation
PRO PIPE
is_lateral_inspection
false