Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2020, 06:11 AM
  • 15 0661_15 0660_06302020_232559.mp4

Date
06/30/2020
W/O
833764
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00602
PipeID
P12553
Time
11:11 PM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7770
Sewer Name
EL MONTE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
WO_833764_TV15005_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0661
Downstream MH
15 0660
Dir. of Survey
Downstream
Length Surveyed
380.8 ft.
Total Length
380.8 ft.
Structural Index
3
Structural Quick
3N2N
Structural Rating
371
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
371
Pipe schematic from manhole 15 0661 to 15 0660
MH: 15 0661MH: 15 0660downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 15 06610 ft. MWM - Water Mark, 35 %of cross sectional area2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start11.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start50.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"146.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"213.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"288.9 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"298.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"378.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish378.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish380.7 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK380.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0660380.8 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    11.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • General Observation - COCKROACHES IN MH

    380.8 ft. - General Observation - COCKROACHES IN MH

Observations (17)

DistanceCodeObservation
2.1SAP
298.1TFC
146.5TF
0MWL
378.2SSS
0MGOCONNECTION AT MH, 3 O'CLOCK
11.1SSS
380.7MGOCONNECTION AT MH, 3 O'CLOCK
50.3TFC
0MGOCOCKROACHES IN MH
0AMH15 0661
378.2SAP
288.9TF
380.8AMH15 0660
0MWM
380.8MGOCOCKROACHES IN MH
213.9TF

Properties (7)

additional_info
SC427455
custom_field_three
SURFACE AGGREGATE, SPALLING
custom_field_two
3
customer
1
datetime
2020-06-30T23:11:19-07:00
documentation
PRO PIPE
is_lateral_inspection
false