Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 18, 2020, 05:35 AM
  • 01 0267_01 0266B_06172020_224007.mp4

Date
06/17/2020
W/O
833688
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00218
PipeID
P01315
Time
10:35 PM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7851
Sewer Name
SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_833688_TV01204_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
18 in.
Upstream MH
01 0267
Downstream MH
01 0266B
Dir. of Survey
Downstream
Length Surveyed
62.1 ft.
Total Length
62.1 ft.
Structural Index
4
Structural Quick
4A00
Structural Rating
48
O&M Index
2
O&M Quick
2A00
O&M Rating
24
Overall Index
3
Overall Quick
Overall Rating
72
Pipe schematic from manhole 01 0267 to 01 0266B
MH: 01 0267MH: 01 0266Bdownstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 01 02670 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK, ACTIVE0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start60 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish60 ft. MGO - General Observation - COCKROACHES IN MANHOLE60 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish62.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK, ACTIVE62.1 ft. AMH - Downstream Manhole, Survey Ends - 01 0266B

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    60 ft. - General Observation - COCKROACHES IN MANHOLE

  • General Observation - CONNECTION AT MH 3 O'CLOCK, ACTIVE

    62.1 ft. - General Observation - CONNECTION AT MH 3 O'CLOCK, ACTIVE

Observations (12)

DistanceCodeObservation
60DAGS
0MGOCOCKROACHES IN MANHOLE
0AMH01 0267
62.1MGOCONNECTION AT MH 3 O'CLOCK, ACTIVE
0MGOCONNECTION AT MH 3 O'CLOCK, ACTIVE
60MGOCOCKROACHES IN MANHOLE
60FM
0MWM
2DAGS
0MWL
2.4FM
62.1AMH01 0266B

Properties (7)

additional_info
SC411292
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2020-06-17T22:35:13-07:00
documentation
PRO PIPE
is_lateral_inspection
false