Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2020, 09:53 AM
  • 01 0265_01 0264_06172020_030552.mp4

Date
06/17/2020
W/O
833688
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00218
PipeID
P01311
Time
2:53 AM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7699
Sewer Name
SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_833688_TV01204_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 0264
Downstream MH
01 0265
Dir. of Survey
Upstream
Length Surveyed
335.2 ft.
Total Length
335.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 0264 to 01 0265
MH: 01 0264MH: 01 0265upstream0 ft. MGO - General Observation - CONNECTION AT MH, 3 OCLOCK, CAPPED0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK, ACTIVE0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Ends - 01 02651.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES, Finish150.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"178.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"333.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES, Start333.2 ft. MLC - Lining Change, Cured in place335.2 ft. MWL - Water Level, 10 %of cross sectional area335.2 ft. MWM - Water Mark, 25 %of cross sectional area335.2 ft. AMH - Downstream Manhole, Survey Begins - 01 0264335.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES, Start

  • Lining Change, Cured in place

    2 ft. - Lining Change, Cured in place

  • General Observation - COCKROACHES IN MANHOLE

    335.2 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
335.2MGOCONNECTION AT MH, 3 OCLOCK, CAPPED
0MWL
335.2MGOCONNECTION AT MH 9 O'CLOCK, ACTIVE
335.2MGOCOCKROACHES IN MANHOLE
0MWM
0AMH01 0264
2DAGS
333.4DAGS
335.2AMH01 0265
156.7TFA
0MGOCONNECTION AT MH 9 O'CLOCK
2MLC
184.5TFA

Properties (7)

additional_info
SC411291
custom_field_three
LIGHT GREASE/LINED WITH CIPP
custom_field_two
3
customer
1
datetime
2020-06-17T02:53:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false