Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 9, 2020, 07:21 AM
  • 01 1404_01 0236_06102020_003655.mp4

Date
06/09/2020
W/O
833688
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00218
PipeID
P01282
Time
12:21 AM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7691
Sewer Name
SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_833688_TV01204_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
12 in.
Upstream MH
01 1404
Downstream MH
01 0236
Dir. of Survey
Downstream
Length Surveyed
140.3 ft.
Total Length
140.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412G
O&M Rating
88
Overall Index
2
Overall Quick
Overall Rating
88
Pipe schematic from manhole 01 1404 to 01 0236
MH: 01 1404MH: 01 0236downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 14040 ft. MGO - General Observation - CONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. MLC - Lining Change, Cured in place13.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"61.3 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS77.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"122.8 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"138.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish138.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish140.3 ft. AMH - Downstream Manhole, Survey Ends - 01 0236140.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Lining Change, Cured in place

    2 ft. - Lining Change, Cured in place

  • General Observation - COCKROACHES IN MANHOLE

    140.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (14)

DistanceCodeObservation
0MWM
77.2TBA
13.1TBA
138.2DSZ
2DAGS
138.2DAGS
0MWL
0AMH01 1404
0MGOCONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK
61.3DSZDEBRIS
140.3AMH01 0236
140.3MGOCOCKROACHES IN MANHOLE
2MLC
122.8TBA

Properties (7)

additional_info
SC411283
custom_field_three
LIGHT GREASE/LINED WITH CIPP
custom_field_two
3
customer
1
datetime
2020-06-09T00:21:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false