G 0113_G 0086_8132020_035054.mp4
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - MISSING TILES 100% START
2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING
5.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CORRODED MISSING REBAR
57.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR
188.9 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open
247.8 ft. - Water Mark, 30 %of cross sectional area
| Distance | Code | Observation |
|---|---|---|
| 188.9 | TF | Open |
| 247.8 | MWM | — |
| 312.1 | SRC | LONG & CIRCUM REBA CORRODED & MISSING |
| 2 | SAM | SEVERE AGG |
| 0 | MWL | — |
| 0 | MGO | MH CONN 3:00 ACTIVE |
| 247.8 | MWL | — |
| 2 | MGO | MISSING TILES 100% START |
| 312.1 | MGO | MISSING TILES 95% FINISH |
| 0 | AMH | 3:50AM |
| 57.5 | SRC | BROKEN REBAR |
| 2 | SRC | LONG & CIRCUM REBAR CORRODED & MISSING |
| 312.1 | MGO | MH CONN 3:00 ACTIVE LARGE INCOMING |
| 313 | AMH | 4:25AM |
| 312.1 | SAM | SEVERE AGG |
| 0 | MGO | MH CONN 3:00 ACTIVE |
| 0 | MWM | — |
| 188.9 | MGO | MISSING TILES 95% START |
| 5.5 | SRC | CORRODED MISSING REBAR |