- Date
- 08/12/2020
- W/O
- 0838950
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z01180
- PipeID
- P01443
- Time
- 4:37 AM
- Certificate
- U_1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1529
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 19
- Purpose
- Capital Improvement Program Assesment
- Project
- 20200811MDM_JOINT_OUTFALL_G_UNIT_8
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 48 in.
- Upstream MH
- G 0116
- Downstream MH
- G 0115
- Dir. of Survey
- Downstream
- Length Surveyed
- 549.8 ft.
- Total Length
- 549.8 ft.
- Structural Index
- 5
- Structural Quick
- 5241
- Structural Rating
- 14
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 19
Pipe schematic from manhole G 0116 to G 0115 Observation photos (7)

0 ft. - General Observation - MH CONN 9:00 ACTIVE -80% GREASE

2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - General Observation - 50% TILES MISSING START

2 ft. - General Observation - 5% MAG COAT START

2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING

146.9 ft. - General Observation - 90% MISSING TILES START

188 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR CORRODED & MISSING