Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 17, 2020, 05:45 AM
Date
07/16/2020
W/O
838814
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00177
PipeID
P10851
Time
10:45 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7924
Sewer Name
JOINT OUTFALL H - UNIT 5A
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
RFIR_WO_838814_TV15130_JUL2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
H 0475
Downstream MH
H 0417
Dir. of Survey
Downstream
Length Surveyed
0 ft.
Total Length
0 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole H 0475 to H 0417
MH: H 0475MH: H 0417downstream0 ft. MGO - General Observation - PIPE IS UNDER CONSTRUCTION. PER LACSD, WRITE-OFF. TO BE RE-ISSUED.

Observations (1)

DistanceCodeObservation
0MGOPIPE IS UNDER CONSTRUCTION. PER LACSD, WRITE-OFF. TO BE RE-ISSUED.

Properties (5)

additional_info
SC411783
customer
1
datetime
2020-07-16T22:45:00-07:00
documentation
PROPIPE
is_lateral_inspection
false