- Date
- 07/07/2020
- W/O
- 838907
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00705
- PipeID
- P14365
- Time
- 1:24 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7818
- Sewer Name
- SOUTH PLANT OUTFALL TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- RFIR_WO_838907_TV18194_JUL2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 18 0510
- Downstream MH
- 18 0511
- Dir. of Survey
- Upstream
- Length Surveyed
- 76.9 ft.
- Total Length
- 76.9 ft.
- Structural Index
- 3
- Structural Quick
- 3222
- Structural Rating
- 10
- O&M Index
- 2
- O&M Quick
- 2B00
- O&M Rating
- 28
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 38
Pipe schematic from manhole 18 0510 to 18 0511 Observation photos (4)

6.9 ft. - Deposits Attached Grease, 0 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

66.1 ft. - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

66.4 ft. - Crack Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

71.3 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES