Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2020, 11:24 AM
  • 18 0525_18 0524 _07062020_042923.mp4

Date
07/06/2020
W/O
838907
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00705
PipeID
P20176
Time
4:24 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7817
Sewer Name
SOUTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_838907_TV18194_JUL2020
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0524
Downstream MH
18 0525
Dir. of Survey
Upstream
Length Surveyed
2.4 ft.
Total Length
2.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 18 0524 to 18 0525
MH: 18 0524MH: 18 0525upstream0 ft. MSA - Survey Abandoned - VIEW OF SIPHON UPLEG0 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: NO2.4 ft. MWL - Water Level, 20 %of cross sectional area2.4 ft. MGO - General Observation - SW BARREL2.4 ft. MWM - Water Mark, 60 %of cross sectional area2.4 ft. AMH - Downstream Manhole, Survey Begins - 18 0524

Observation photos (1)

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: NO

    2.4 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: NO

Observations (6)

DistanceCodeObservation
0MWL
2.4MSAVIEW OF SIPHON UPLEG
0MGOSW BARREL
0MWM
0AMH18 0524
2.4CM

Properties (7)

additional_info
SC411627
custom_field_three
CRACK MULTIPLE
custom_field_two
3
customer
1
datetime
2020-07-06T04:24:26-07:00
documentation
PROPIPE
is_lateral_inspection
false